ConvNeXt-V2-Tiny classifies pediatric radiographs as bacterial pneumonia, normal or viral pneumonia. Explore the classification errors.
Replayed on the original 624-image test fold
| Metric | Value |
|---|---|
| Accuracy | 91.35% |
| Macro F1 | 90.30% |
| Macro AUROC (OvR) | 97.53% |
The complete confusion matrix and metrics reproduce the stored main report. Historical checkpoint training membership is unrecorded; the baseline remains a stored report.
Evaluation record · Pinned model
Evaluation protocol and numerical parity. The DINOv2 baseline remains a separately stored report; its checkpoint is absent from this snapshot.
This explicit torchvision recipe preserves the exact training/evaluation geometry and uses native safetensors weights.
import torch
from PIL import Image
from torchvision.transforms import v2
from transformers import AutoModelForImageClassification
REPO = "kiselyovd/chest-xray-classifier"
REVISION = "09bd78b58c657870961faa1b79699da5ca8bc796"
model = AutoModelForImageClassification.from_pretrained(
REPO, revision=REVISION, use_safetensors=True, trust_remote_code=False
).eval()
transform = v2.Compose([
v2.ToImage(), v2.Resize(255, antialias=True), v2.CenterCrop(224),
v2.ToDtype(torch.float32, scale=True),
v2.Normalize([0.485, 0.456, 0.406], [0.229, 0.224, 0.225]),
])
image = Image.open("chest-xray.jpeg").convert("RGB")
with torch.inference_mode():
scores = model(pixel_values=transform(image).unsqueeze(0)).logits.softmax(-1)[0]
print([(model.config.id2label[i], float(scores[i])) for i in scores.argsort(descending=True).tolist()])
Class order is 0 bacterial, 1 normal, 2 viral. Scores are uncalibrated model outputs. The corrected native processor includes a small MIT-licensed adapter that preserves torchvision's rounded center-crop anchor. Loading that adapter with AutoImageProcessor requires reviewing the pinned module and explicitly setting trust_remote_code=True; the standalone recipe above uses standard torchvision code.
The original Kaggle dataset contains 5856 pediatric radiographs. The repository derives bacterial/viral subtypes from the original pneumonia filenames. Replaying all 624 original test images reproduces the complete stored main confusion matrix and its metrics. A saved probability/target archive allows independent recalculation.
Source receipt · Test-file manifest · Complete processor comparison.
Historical training membership and patient-level independence are unrecorded. This is research on a limited pediatric cohort; clinical validation has not been performed.
Project code and the adapter are MIT. The source data are CC BY 4.0, attributed to Daniel Kermany, Kang Zhang and Michael Goldbaum; original dataset DOI 10.17632/rscbjbr9sj.2. ConvNeXt-V2 and DINOv2 base cards declare Apache 2.0. The fine-tuned artifact's MIT declaration does not replace those upstream notices or dataset attribution.
model.safetensors 111 MBreports/replay-native-2026-10-15.npz 8.8 kBfacebook/convnextv2-tiny-22k-224