LumoHub IMU Burst 1D-CNN (LumoBurst1DCNN) — Approach 1
End-to-end 1D Convolutional Neural Network running directly on the LumoHub (ESP32-S3) to eliminate wearable wrist false alerts and classify 3.0-second 6-axis IMU burst sequences (30 samples x 6 channels at 10 Hz) received from the wearable over BLE (0x03 MPU6050 diagnostic stream).
Architecture
- Input:
[30, 6]normalized(ax/8g, ay/8g, az/8g, gx/250dps, gy/250dps, gz/250dps) - Backbone:
Conv1D(6->24, k=5)+ ReLU +MaxPool(2)->Conv1D(24->32, k=3)+ ReLU +MaxPool(3) - Dual Pooling: Concatenated
GlobalAvgPool1D+GlobalMaxPool1D(64dims) - Head:
Linear(64->32)+ ReLU +Linear(32->5) - Footprint:
5,325parameters (21,300bytes Flash),58,368MACs/inference
5-Class Taxonomy
NORMAL_ADL— Walking, sitting, lying down smoothly, everyday movementWRIST_SHOCK_FALSE_ALERT— High-G wrist shock (clapping, table slap, knocking) without body collapseDEVICE_DROP_OFF_WRIST— Unbuckled/dropped wearable onto a rigid surface (zero physiological tremor)SOFT_FALL_RECOVERING— Stumble/fall with posture collapse followed by self-recovery motionCRITICAL_FALL_IMMOBILE— Severe fall with posture collapse and prolonged immobility
Benchmark Metrics (Held-out Test Split, N = 4,500)
- Accuracy:
98.38% - Macro F1:
98.38% - Wrist-Shock False Alert Rate:
0.11% - Device Drop-Off False Alert Rate:
0.00% - Binary Fall Sensitivity (Classes 3 & 4):
99.33%
BLE Packet Drop & Noise Stress Test
| Scenario | Accuracy | Macro F1 |
|---|---|---|
| Clean 10Hz BLE (0% loss) | 98.38% | 98.38% |
| BLE Packet Drop 10% | 93.60% | 93.62% |
| BLE Packet Drop 25% | 85.18% | 85.28% |
| BLE Packet Drop 40% | 75.16% | 75.40% |
| High Sensor Noise (2x) | 98.44% | 98.44% |
Embedded Firmware Integration
Folded C99 weights are exported in lumo_hub_cnn_model.h for zero-dependency inference on ESP32-S3 (lumo_imu_ai.c).